Duikmateriaal
The XTX50 regulator can be converted from a right handed hose configuration (as supplied from the APEKS factory in the standard) to a left handed one. This feature is known as the Reversible Venturi System (RVS). Changing the regulator to a left handed configuration is both quick and simple and can be performed by any APEKS Authorised Service Technician.
The XTX50 regulator incorporates the new feature of Diver Changeable Exhausts system (DCE). This system gives the diver the ability to change from a small exhaust tee to a large exhaust tee. This gives the user a choice of the wider exhaust tee for minimal bubble interference (essential for underwater photography) and the narrow exhaust tee for a smaller compact comfortable regulator (ideal for use as an octopus regulator).
The XTX50 regulator incorporates a new two-shot high strength plastic front cover, improving the durability of the most vulnerable part of the demand valve.
The new ergonomic Venturi lever of the XTX50 has been designed to reduce the amount of grit ingress.
A new swivel hose connection is available at an extra cost. This allows the demand valve end of the hose connection to rotate and pivot, providing a more comfortable fit.
A new silicone exhaust valve has been used on the XTX50 regulator improving breathing performance.
- Pneumatically-balanced second stage results in smooth, easy breathing.
- The XTX purge buttons are large and easy to operate. A 2-stage progressive purge is used – press the purge on the side for a lower flow rate, useful where more control is required such as filling lift bags etc, then press in the centre for the full effect of the purge, i.e. when regulator clearing etc.
- The large venturi lever has a soft touch rubber grip, which makes it easier to locate and use. The lever reduces the amount of grit ingress and therefore resists any possible friction giving a smooth operation.
- Easy-to-grip opening effort control knob keeps the diver in control.
- The second stage is manufactured with active protection against infection as all molded parts are produced with an additive that kills MRSA, protects against E-Coli, bacteria and fungi, and is also very effective against viruses, mould, yeast and algae.
- A silicone exhaust valve improves the breathing performance of the regulator.
- The Comfo-bite™ mouthpiece virtually eliminates jaw-fatigue.
- A heat exchanger (patented) which surrounds the valve mechanism, dissipates the cold caused by gas expansion while drawing in the warmth of the ambient water.
First Stage
- Draaibare kop met 4 lage poorten.
- 4 lage druk poorten, 4 x 3/8″ UNF.
- 2 hoge druk poorten, 2 x 7/16″ UNF.
- Gepolijste chrome afwerking.
- Gesloten membraan eerste trap.
- Gebalanceerd systeem voor uitstekende prestaties.
Second Stage
- Geïntegreerd venturi systeem.
- Gebalanceerde tweede trap.
- Geschikt voor koud water duiken.
- Gepolijst chrome afwerking.
- Tweede trap om te bouwen van een linkse naar een rechtse configuratie.
- Uitwisselbare uitblaas gedeelte om te van groot naar klein.
- Pneumatically-balanced second stage results in smooth, easy breathing.
- The XTX purge buttons are large and easy to operate. A 2-stage progressive purge is used – press the purge on the side for a lower flow rate, useful where more control is required such as filling lift bags etc, then press in the centre for the full effect of the purge, i.e. when regulator clearing etc.
- The large venturi lever has a soft touch rubber grip, which makes it easier to locate and use. The lever reduces the amount of grit ingress and therefore resists any possible friction giving a smooth operation.
- Easy-to-grip opening effort control knob keeps the diver in control.
- The second stage is manufactured with active protection against infection as all molded parts are produced with an additive that kills MRSA, protects against E-Coli, bacteria and fungi, and is also very effective against viruses, mould, yeast and algae.
- A silicone exhaust valve improves the breathing performance of the regulator.
- The Comfo-bite™ mouthpiece virtually eliminates jaw-fatigue.
- A heat exchanger (patented) which surrounds the valve mechanism, dissipates the cold caused by gas expansion while drawing in the warmth of the ambient water.
- Top performance cold water-ready, balanced SCUBA regulator, DIN
- Balanced 2nd stage inhalation and air-flow controls are easy to use
- 2nd stage inhalation and air-flow controls are easy to use
- HP outlets: 2, 4 LP outlets: 2 inclined at 20 degrees, 2 inclined at 30 degrees to reduce hose strain and drag
- Removable stainless steel 1st stage valve seat extends service life
DX200 ICE regulator
First stage material: Forged brass with sanded chrome finish.
First stage features: High-performance balanced diaphragm, total insulation from outside, maximum safety and simplicity during maintenance.
Second stage material: technopolymers, elastomers, with components in metal and covered with “Luxury Technology” treatment for abrasion resistance.
Second stage features: Possibility to regulate both respiratory exertion and the Venturi effect.
HP outlets: 2
LP outlets: 4, of which 2 inclined at 20° and 2 inclined at 30°.
X100 Octopus
X100 Octo material: technopolymers, elastomers and ultralight alloys (Hi-Flex hose included).
Seac MX100 DIN 300 bar, 1st stage + 2nd stage regulator for scuba diving
Balanced 2nd stage is lightweight with low-friction mechanics for easy, natural breathing
Environmentally isolated, balanced diaphragm 1st stage delivers consistent performance as tank pressure changes
2 high-pressure outlets and 4 low-pressure outlets
2nd stage Venturi control
MX100 combines safety, high performance, and a robust structure suitable for all divers, even beginners who are looking for a reliable diaphragm regulator.
The balanced first stage has a heat exchange system, designed especially for cold water.
The removable stainless steel valve seat can easily be replaced during maintenance.
The first stage has 2 HP and 4 LP outlets ports.
The second stage has a simple Venturi effect lever making it is possible to adjust easily.
The OWS front cover design system prevents free-flow even in strong currents.
The chromed brass first stage of the MX100, as well as the robust simplicity of the second stage, not only significantly reduces the overall weight of the regulator but also maintenance costs.
Available with DIN 300 BAR and INT 230 BAR. All SEAC regulators are Made in Italy.
First stage
Balanced first stage designed for increased heat transfer, even in cold water. Removable stainless steel valve seat. 2 high-pressure and 4 low-pressure outlets.
Second stage
Second stage with adjustable Venturi effect by means of a simple lever. The OWS system prevents self-priming in the event of strong current.
Available with DIN 300 BAR and INT 230 BAR connections.
Made in Italy and assembled in our factories.
SEACSUB brings you the new MX100 300 DIN regulator, it includes the MX100 regulator and the octopus or octopus X100 with a type of DIN connection. With 4 LP outlets and 2 HP outlets that regulate the air flow naturally to reduce the athlete´s inhalation effort.
The hoses are covered in special anti-tear and scratch material. The first stage is made of chromed brass and the second stage is made of technopolymers and elastomers that provide greater resistance to corrosion protection. It is perfect for recreational diving since it is very easy and safe to use. Set including MX100 regulator and X100 Octopus, available in DIN and INT Version. Mate Octo HD bag included.
If you are looking for an online store specialized in dive equipment, discover diveinn. As SEAC authorized dealer, all of our dive products have the full manufacturer warranty of SEAC. Select one of our Regulators categories and discover the range of Regulators products that we have for your favorite activity like SEACMX100 300 DIN Regulator Set. To clear out any doubts, contact our team via telephone or email. Do not wait any longer!
First stage for dry suit inflation devices.
Two types of first stages:
DIN GAS 5/8 compact first stage with integrated low profile pressure relief valve. Two low (3/8 UNF) outputs (one of the outputs is already occupied by the pressure relief valve) and one high (7/16 UNF) output.
First stage W21.8 specific inert gas with integrated pressure relief valve. 1 high output (7/16 UNF) and 1 low output (3/8 UNF)